Short answer

A furnace blows cold air when the blower runs but the burners aren’t lit or have shut off. The most common causes are a thermostat fan set to ON instead of AUTO, a clogged filter tripping the high-limit switch, a dirty flame sensor, and, on high-efficiency furnaces, a frozen or blocked PVC vent or condensate line. The first two you can fix yourself in five minutes.

First: is it actually a problem?

Two moments of cool air are normal.

When a gas furnace starts, it runs a small inducer fan, lights the burners and warms the heat exchanger before the main blower comes on. If your ducts run through a cold attic or garage, the first air out of the vents can still feel cool for a minute while the ductwork warms up. At the end of a cycle, the blower keeps running briefly after the flames go out to pull the last heat off the heat exchanger. That air cools down fast.

If the air stays cool for more than a few minutes, or the house keeps getting colder, something is wrong. Keep reading.

One more case: if you have a heat pump (or a dual-fuel system), the air normally comes out in the mid-90s °F. That feels cool on your hand even while it’s heating the house. See do heat pumps work in Northern Virginia winters?

Quick diagnosis by symptom

What you noticeMost likely causeDIY or call?
Cool air blows nonstop, even between heating cyclesThermostat fan set to ONDIY: switch to AUTO
Warm air for a few minutes, then cold, then repeatsDirty filter tripping the high-limit switchDIY: replace filter. Call if it keeps happening
Burners light, then go out within a few secondsDirty or failing flame sensorCall (or clean only if you’re comfortable working inside the furnace)
You hear the inducer fan, but the burners never lightIgnitor, gas supply, or a pressure switch faultCall
High-efficiency furnace quits during a hard freeze or after snowFrozen condensate line, or snow or ice blocking the PVC ventsCheck the vents outside. Call if clear
Some rooms get warm air, others stay coldLeaky or disconnected ducts, closed dampersCall

The 8 most common causes

1. The thermostat fan is set to ON

This is the most common cause, and it costs nothing to fix. With the fan on ON, the blower runs all the time, including between heating cycles when the burners are off. That in-between air is room temperature, which feels cold coming out of a vent. Set the fan to AUTO so it only runs while the furnace is actually heating.

While you’re there, confirm the mode says HEAT, the set temperature is above room temperature, and (if it uses batteries) the display isn’t fading.

2. A clogged air filter

A filter packed with dust starves the furnace of air. The heat exchanger overheats, and a safety device called the high-limit switch shuts the burners off while the blower keeps running to cool things down. You get warm air, then cold air, then warm air again.

Pull the filter and hold it up to a light. If you can’t see light through it, replace it. Most 1-inch filters need changing every 1 to 3 months in heating season. Our guide on how often to change your air filter covers the details. If a new filter doesn’t stop the cycling, the limit may be tripping for another reason (a weak blower motor, blocked returns, or a heat exchanger problem), and that needs a technician.

3. A dirty flame sensor

The flame sensor is a thin metal rod that sits in the burner flame. Its job is to prove the flame is there. When it gets coated with residue, the control board can’t “see” the flame and shuts the gas off a few seconds after lighting as a safety measure. The furnace then tries again, and again, and may lock itself out.

It’s usually a quick fix: clean the rod or replace it. Cleaning means shutting off power and gas and removing the sensor from the burner assembly. We recommend leaving that to a technician unless you’ve done it before. A fall furnace tune-up includes it.

4. Ignition problems

Most furnaces installed in the last 20+ years use a hot surface ignitor, a small element that glows orange to light the gas. Ignitors are brittle and wear out. If you hear the inducer fan start and then nothing lights, a cracked ignitor is a common culprit. Older furnaces with a standing pilot have their own issues, covered in pilot light keeps going out.

5. Gas supply

Check that the gas shutoff valve next to the furnace is open (the handle runs parallel to the pipe). If your gas stove or gas water heater also isn’t working, the problem is upstream of the furnace. If you smell gas at any point, don’t touch switches or the thermostat. Leave the house and call your gas utility’s emergency line or 911 from outside.

6. Frozen condensate line or blocked PVC vents (high-efficiency furnaces)

This one is very much a Northern Virginia winter problem. High-efficiency furnaces (90% AFUE and up) vent through two white PVC pipes, usually out a side wall, and drain water through a condensate line. During a hard freeze, a drain line that runs through a cold garage, crawlspace or outside wall can freeze. Water backs up, and the pressure switch shuts the furnace down to prevent damage. A snowdrift, or ice from a dripping gutter, covering the PVC pipes outside does the same thing.

Go outside and look at the two PVC pipes. Clear away snow and ice by hand, gently. If the vents are clear and the furnace still won’t light, or it locks out every cold night, call us. Insulating or re-routing the condensate line usually solves it for good.

7. Leaky or disconnected ductwork

If the furnace is producing heat but one part of the house gets cold air, the heat may be escaping before it reaches the room. A duct that has separated in an attic or crawlspace can dump warm air outside the living space while pulling in cold air. Check that supply registers are open, then have the ductwork inspected.

8. A control board or safety fault

Modern furnaces have a small light on the control board that blinks a code when something is wrong. Before you call, look through the small window on the furnace door, count the blinks, and match them to the chart printed on the inside of the furnace door. Telling the dispatcher “three blinks, pressure switch” saves real time on the service call.

What you can safely check yourself

  1. Set the thermostat to HEAT, fan to AUTO, and raise the set temperature 3–5 degrees.
  2. Replace the thermostat batteries if it uses them.
  3. Replace the air filter.
  4. Check the furnace power switch (it looks like a light switch on or near the unit) and the breaker.
  5. Make sure the furnace door panel is fully closed. Many furnaces won’t run with it loose.
  6. Confirm the gas valve at the furnace is open.
  7. On a high-efficiency furnace, check that the outdoor PVC pipes are clear of snow, ice and leaves.
  8. Turn the furnace off for 30 seconds and back on to reset a lockout. If it locks out again, stop and call.

Our emergency checklist for when your heat goes out covers how to keep the family and the pipes safe while you wait.

When to stop and call

  • You smell gas, or a carbon monoxide alarm goes off. Get everyone out, then call the gas utility or 911 from outside.
  • The high-limit switch keeps tripping with a new filter in.
  • The furnace locks out repeatedly or shows the same error code.
  • You see soot, scorch marks or water around the furnace.
  • The burners light but the flame looks lazy, yellow or rolls out of the burner area.

Frequently asked questions

Why is my furnace running but blowing cold air?

The blower is running without the burners lit. Most often the thermostat fan is set to ON, the filter is clogged and has tripped the high-limit switch, or the flame sensor is dirty and shutting the burners off. On high-efficiency furnaces, a frozen condensate line or blocked PVC vent is also common in winter.

Can a dirty filter make a furnace blow cold air?

Yes. A clogged filter restricts airflow, the furnace overheats, and the high-limit switch shuts off the burners while the blower keeps running. You’ll typically get warm air, then cold, then warm again. Replacing the filter often fixes it.

Is it normal for a furnace to blow cold air at first?

Briefly, yes. The blower starts after the burners warm the heat exchanger, but ducts in a cold attic or garage can make the first air feel cool for a minute. Cool air for more than a few minutes isn’t normal.

How much does it cost to fix a furnace blowing cold air?

It depends on the cause. A thermostat setting or a new filter costs little or nothing. Cleaning a flame sensor or clearing a condensate line is usually a standard service call. An ignitor, pressure switch or control board replacement costs more. A technician can tell you the exact cause and price before doing the work.

Why does my high-efficiency furnace stop working when it’s very cold outside?

Often the condensate drain line has frozen, or snow and ice are blocking the PVC intake or exhaust pipes. The pressure switch then shuts the furnace down for safety. Clear the outdoor vents first. If it keeps happening, the drain line needs insulating or re-routing.